锂离子电池过放电状态的阻抗特性研究*

Study on Impedance Characteristics of Lithium-ion Battery in Over Discharge State

  • 摘要: 目前锂电池被广泛应用于电化学储能系统,但由于电池单体间的差异,单体电池常常存在过放电现象,给电池模组及储能系统的应用带来安全隐患,因此对过放电状态的锂电池进行检测与分析对于其安全应用具有重要意义。本文设计了正常循环和不同程度过放电的电池循环试验,利用弛豫时间分布法、阻抗差异分析法和容量增量法对过放电状态的锂离子电池全寿命周期内的阻抗特性进行分析。结果表明,过放电会加速电池老化,可提高充放电过程温升;相较于正常循环,过放电循环使电池欧姆内阻与电荷转移电阻增大,SEI膜内阻减小,电荷传递电阻无明显变化,锂离子固相扩散电阻随着过放电程度增加,先减小后增大。本文结果为锂电池过放电内部特性研究和过放电检测提供理论依据。

     

    Abstract: At present, lithium-ion batteries are widely used in electrochemical energy storage systems. However, due to the differences between batteries, single batteries often have over discharge phenomenon, which brings safety risks to the application of battery modules and energy storage systems. Therefore, the detection and analysis of lithium-ion batteries in over discharge state are of great significance for their safety applications. Cycle tests of normal cycle and different degrees of over discharge are designed. The relaxation time distribution method, impedance difference analysis method and capacity increment method are used to analyze the impedance characteristics of lithium-ion batteries in the whole life cycle of over discharge state. The results show that over-discharge can accelerate battery aging and increase the temperature rise during charging and discharging. Compared with the normal cycle, the ohm internal resistance and charge transfer resistance increase in the over discharge cycle, the internal resistance of SEI film decreases, and the charge transfer resistance has no significant change. The solid-phase diffusion resistance of lithium-ion decreases first and then increases with the increase of over discharge degree. The results provide a theoretical basis for the study of the internal characteristics of lithium-ion battery over discharge and the detection of over discharge.

     

/

返回文章
返回