表1 IES中的各设备参数及运行费用
|
| |
|
设备 名称 | 台数 | 额定 功率/kW | 运行维护 系数Cm/ [元/(kW·h)] | 安装成本CINS/ (万元/kW) | 寿命 L/年 | | WT | 2 | 120 | 0.029 6 | 2.375 | 10 | | PV | 3 | 80 | 0.009 6 | 6.650 | 20 | | GT | 3 | 1 000 | 0.030 0 | 1.667 | 15 | | GB | 2 | 1 200 | 0.028 7 | 1.569 | 20 | | P2G | 1 | 150 | 0.021 5 | 2.457 | 10 | | HRS | 1 | 1 000 | 0.017 6 | 1.284 | 10 | | EH | 1 | 500 | 0.018 0 | 1.476 | 15 | | AC | 1 | 500 | 0.023 9 | 2.091 | 15 | | EC | 2 | 800 | 0.030 2 | 1.919 | 15 | | SB | 1 | 220 | 0.028 3 | 1.894 | 10 | | WS | 1 | 800 | 0.015 7 | 1.113 | 20 |
|
|
|