基于介电响应特性的油浸式电力变压器绝缘状态评估研究进展
|
|
余浩, 黄彦钦, 尹钧毅, 孟国栋, 成永红
|
Review Progress on Insulation Condition Assessment of Oil Immersed Power Transformer Based on Dielectric Response Characteristics
|
|
YU Hao, HUANG Yanqin, YIN Junyi, MENG Guodong, CHENG Yonghong
|
|
| |
| |
|
| 模型函数 | 复介电常数 | 复平面图 | | Debye | ${{\varepsilon }^{*}}={{\varepsilon }_{h}}+\frac{\Delta \varepsilon }{1+jw\tau }$ | | | Cole-Cole | $\begin{matrix} & {{\varepsilon }^{*}}={{\varepsilon }_{h}}+\frac{\Delta \varepsilon }{1+{{(jw\tau )}^{1-\alpha }}} \\ & \ \ \ \ \ \ (0<\alpha <1) \\ \end{matrix}$ | | | Davidson-Cole | $\begin{matrix} & {{\varepsilon }^{*}}={{\varepsilon }_{h}}+\frac{\Delta \varepsilon }{1+{{(jw\tau )}^{\beta }}} \\ & \ \ \ \ \ \ (0<\beta <1) \\ \end{matrix}$ | | | Havriliak-Negami | $\begin{matrix} & {{\varepsilon }^{*}}={{\varepsilon }_{h}}+\frac{\Delta \varepsilon }{{{[1+{{(jw\tau )}^{1-\alpha }}]}^{\beta }}} \\ & \ \ \ \ \ \ (0<\alpha <1,\ \ 0<\beta <1) \\ \end{matrix}$ | |
|
|
|